Q1. An administrator is troubleshooting a CPU performance issue for a virtual machine. Which three esxtop counters may demonstrate CPU contention? (Choose three.)
A. %RDY
B. %RUN
C. %MLMTD
D. %WAIT
E. %CSTP
Answer: A,C,E
Q2. When attempting to place a datastore in Maintenance Mode, the task remains at 1%. What are two potential causes for this? (Choose two.)
A. Storage DRS is disabled on one or more virtual machine(s) disk(s).
B. Storage DRS rules prevent migration recommendations for the disk.
C. Storage DRS datastores have insufficient space to accommodate failover.
D. Storage DRS provisioning network has been limited with I/O control policies.
Answer: A,B
Q3. An administrator created a six node Virtual SAN cluster, created a fault domain, and moved three of the six nodes into that domain.
A node that is a member of the fault domain fails.
What is the expected result?
A. The remaining two fault domain members are treated as failed.
B. The remaining two fault domain members stay protected by the domain.
C. One of the non-member nodes will be automatically added to the fault domain.
D. VMware High Availability will restart virtual machines on remaining nodes in the domain.
Answer: A
Q4. Which VMware Single Sign-On component issues Security Assertion Markup Language (SAML) tokens?
A. VMware Security Token Service
B. Administration Server
C. VMware Directory Service
D. Identity Management Service
Answer: A
Q5. Refer to the Exhibit.
What will be the result of selecting the highlighted device?
A. Datastore will grow up to 200.01GB using the remaining free space on the device.
B. Datastore will add 200.01GB by adding the device as a second extent.
C. The device size can be expanded to be larger than 200.01 GB in size.
D. The device is not suitable for this operation.
Answer: A
Q6. Which two are valid Identity Sources when configuring vCenter Single Sign-On? (Choose two.)
A. Radius
B. NIS
C. OpenLDAP
D. LocalOS
Answer: C,D
Q7. An administrator is configuring virtual machines to use Worldwide Port Names (WWPNs) to access the storage.
Which two conditions are required? (Choose two.)
A. The switches in the fabric must be N-Port ID Virtualization aware.
B. The virtual machines must be using passthrough Raw Disk Mapping (RDMp).
C. The virtual machines must be using Virtual Machine Disk (VMDK).
D. The switches in the fabric must be Storage I/O Control aware.
Answer: A,B
Q8. What command line utility can be used to upgrade an ESXi host?
A. esxcli
B. esxupdate
C. vihostupdate
D. esxcfg
Answer: A
Q9. Refer to the Exhibit.
An administrator is attempting to enable Enhanced vMotion Compatibility (EVC), but receives the error shown in the Exhibit.
Which condition would explain the error?
A. The ESXi hosts are not licensed for EVC.
B. The administrator does not have privileges to enable EVC.
C. The ESXi host CPU has the Intel No-Execute feature disabled.
D. The administrator has turned on Intel Virtualization Technology.
Answer: C
Q10. An administrator is attempting to enable Fault Tolerance on a virtual machine with 4 vCPUs and observes the following in the vSphere Web Client:
Fault Tolerance has not been licensed on host <hostname>.
What is the minimum licensed edition that supports this configuration?
A. Enterprise
B. Enterprise Plus
C. Standard
D. Essentials Plus
Answer: A