300-160 Exam - DCID Designing Cisco Data Center Infrastructure

certleader.com

Act now and download your today! Do not waste time for the worthless tutorials. Download with real questions and answers and begin to learn with a classic professional.

Online Cisco 300-160 free dumps demo Below:

NEW QUESTION 1
Which technology can you use to create separate routing tables for different tenants that are hosted on the same Cisco NX-OS platform?

  • A. Cisco FabricPath
  • B. VLANs
  • C. vPC
  • D. VRF

Answer: D

Explanation: http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/nx-os/vxlan/configuration/guide/b_NX-OS_VXL

NEW QUESTION 2
In a three-tier SAN topology, which network layer should you connect the SAN initiators to?

  • A. storage edge
  • B. core
  • C. host edge
  • D. distribution

Answer: C

NEW QUESTION 3
When migrating an existing data center network to a unified fabric network, which transitions should you expect to see?

  • A. IOS to Nexus networking equipment
  • B. physical to virtual machines
  • C. Fibre Chanel to FCoE
  • D. iSCSI to NAS

Answer: C

NEW QUESTION 4
Which option accurately describes the OSPF Graceful Restart feature in Cisco NX-OS?

  • A. keeps the control plane state active during an OSPF process restart
  • B. shuts down the OSPF process gracefully to replace the router
  • C. prevents the OSPF process from restarting when the process crashes
  • D. allows a router to remain in the data forwarding path during an OSPF process restart

Answer: D

Explanation: A graceful restart, or nonstop forwarding (NSF), allows OSPFv2 to remain in the data forwarding path through a process restart. When OSPFv2 needs to perform a graceful restart, it sends a link-local opaque (type 9) LSA, called a grace LSA
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/4_2/nx-os/unicast/configuration/guide/l3_cli_nxos

NEW QUESTION 5
Why would you configure FCoE to use jumbo frames?

  • A. to enable the network to create a no-drop CoS
  • B. to provide a credit-based flow control mechanism
  • C. to prevent a Fibre Channel frame from being split into two Ethernet frames
  • D. to provide prioritized processing that is based on bandwidth allocation and low latency

Answer: B

NEW QUESTION 6
Which statement accurately describes the configuration requirements for disjoint Layer 2 networks on Cisco UCS?

  • A. The Cisco UCS fabric Interconnect must be in switch mode.
  • B. The VLAN IDs must overlap in both Layer 2 domains.
  • C. All of the uplinks most be in one port channel to keep all of the ports active.
  • D. The Cisco UCS Fabric Interconnect must be in end-host motto.

Answer: D

NEW QUESTION 7
Spanning Tree Protocol runs at which functional layer of the data center?

  • A. core layer
  • B. access layer
  • C. application layer
  • D. network layer

Answer: B

NEW QUESTION 8
LISP provides which capability?

  • A. host connectivity redundancy
  • B. physical host mobility
  • C. VM mobility
  • D. VXLAN mobility

Answer: B

NEW QUESTION 9
Which statement accurately describes VSAN-based QoS when the same flow is present in two class maps that are associated to a policy map?

  • A. The highest QoS value is used.
  • B. The lowest QoS value is used.
  • C. The QoS value of the class map that is attached first takes effect.
  • D. The QoS value of the class map that is attached last takes effect.

Answer: C

Explanation: http://www.cisco.com/en/US/products/ps5989/products_configuration_guide_chapter09186a0080663141.html

NEW QUESTION 10
You are configuring a switch as a LISP xTR. You plan to use the LISP xTR when deploying redundant map servers. Which action do you take?

  • A. Register the LISP xTR to the anycast IP address of the map resolver.
  • B. Register the LISP xTR to the IP address of each map server
  • C. Configure the map notify group command by using the anycast IP address of the map resolver
  • D. Configure the map-notify group command by using the IP address of each map server

Answer: C

NEW QUESTION 11
Which two actions must be performed when you configure Cisco VN-Link in hardware? (Choose two.)

  • A. Create a distributed virtual switch in Cisco UCS Manager.
  • B. Add an ESX host to the distributed virtual switch in Cisco UCS Manager.
  • C. Create a port profile and profile clients in Cisco UCS Manager.
  • D. Create a standard switch on an ESXi host and map the network adapters to the switch.
  • E. Create a distributed virtual switch under the datacenter folder in VMware vCenter.

Answer: AC

NEW QUESTION 12
Which technology uses TCP as a block I/O transport?

  • A. iSCSI
  • B. NFS v4
  • C. CIFS
  • D. FCoE

Answer: A

NEW QUESTION 13
Refer to the Exhibit.
300-160 dumps exhibit
You need to allocate all interfaces on the same port ASIC to the same VDC. Which ports share an ASIC?

  • A. ports 1-12
  • B. ports 9-17
  • C. ports 9-13
  • D. ports 1-17

Answer: A

NEW QUESTION 14
You are designing a Cisco Fabric interconnect blade chassis and stand alone UCS server solution for a large public cloud provider the design includes these items
One upstream cisco nexus 7000 series switches that provides LAN and SAN connectivity Ten Fabric interconnect switches (five pair in high availability)
Five fully equipped cisco UCS blade chassis per fabric interconnect switches pair Fifty cisco UCS stand alone servers
Which statement ae true regarding San connections from the fabric interconnect switches to the upstream cisco nexus 7000 series switch? (choose two)

  • A. Fabric interconnect switches must be design in end host mode
  • B. The maximum no of domain ids that can be addressed by the fiber channel protocol 355
  • C. Cisco UCS blade server and stand server must be connected to the SAN directly
  • D. The cisco nexus 7000 switches must deploy NPIV
  • E. Fabric interconnect Switch must be design in switch Mode

Answer: AD

NEW QUESTION 15
Which two options represent an access layer solution designed to accelerate server virtualization, that is managed just like other network devices in the data center? (Choose two)

  • A. MPIO
  • B. host vPC
  • C. VEM
  • D. VSS
  • E. VSM

Answer: CE

Explanation: When server virtualization is implemented, the edge of the network is pushed from the traditional location in the network access layer, implemented in physical switches, to the virtual network access layer that is implemented in software in the server hypervisor. The Cisco Nexus 1000V Switch is an intelligent virtual network access layer switch that runs Cisco NX-OS Software, Cisco's data center operating system that runs on all Cisco data center products. Operating inside the Microsoft Hyper-V hypervisor, the Cisco Nexus 1000V supports Cisco Virtual Network Link (VN-Link) server virtualization technology to provide:
300-160 dumps exhibit Policy-based virtual machine connectivity
300-160 dumps exhibit Mobile virtual machine security and network policy
300-160 dumps exhibit Nondisruptive operating model for your server virtualization and networking teams
When server virtualization is implemented in the data center, servers and virtual machines are not managed the same way as physical servers. Server virtualization is treated as a special deployment, leading to longer
deployment time, with more coordination needed among server, network, storage, and security administrators. With the Cisco Nexus 1000V, you have a consistent networking feature set and configuration and provisioning model for both the physical and the virtual networks. Virtual machine networks can use the same network configuration, security policy, diagnostic tools, and operating models as physical server deployments that are connected to physical switches. This unified approach provides faster deployment and troubleshooting and makes the administration of virtualization environments essentially the same as for nonvirtualized deployments.
Developed in close collaboration with Microsoft, the Cisco Nexus 1000V Switch is certified by Microsoft and integrates with Microsoft Windows Server and Microsoft System Center Virtual Machine Manager
(SCVMM). You can use the Cisco Nexus 1000V to manage your virtual machine connectivity with confidence
in the integrity of the server virtualization infrastructure.
Cisco Nexus 1000V Switch Components
Cisco Nexus 1000V Switches have two main components:
300-160 dumps exhibit Virtual supervisor module (VSM)
300-160 dumps exhibit Virtual Ethernet module (VEM)
The VSM provides the switch control and management plane, and the VEM provides the data plane for the switch (Figure 1). The VSM can run as a virtual machine on any Microsoft Hyper-V host or as a virtual service node on the Cisco Nexus 1010 and 1110. The VEM runs as a plug-in (extension) to the Microsoft Hyper-V switch in the hypervisor kernel, providing switching between virtual machines.
Cisco Nexus 1000V sees the VSMs and VEMs as modules. In the current release, a single VSM can manage up to 64 VEMs. The VSMs are always associated with slot numbers 1 and 2 in the virtual chassis. The VEMs are sequentially assigned to slots 3 through 66 based on the order in which their respective hosts were added to the Cisco Nexus 1000V Switch.

NEW QUESTION 16
Which two components are contained within a device package that is installed on a cisco APIC?

  • A. A device SDK
  • B. A device driver
  • C. A device Specification
  • D. Device script
  • E. Device management software

Answer: CD

NEW QUESTION 17
Which two FEX topologies trade deterministic bandwidth for server-link stability during FEX uplink failure? (Choose two.)

  • A. port channel
  • B. static pinning
  • C. virtual port channel
  • D. dynamic pinning
  • E. Equal-Cost Multipath
  • F. RPVST

Answer: AC

NEW QUESTION 18
Drag and drop the feature descriptions from the left onto the correct types of VDCs on the right
300-160 dumps exhibit

    Answer:

    Explanation: 300-160 dumps exhibit

    NEW QUESTION 19
    You must use one logical uplink for Fibre Channel traffic and Ethernet traffic on a Cisco UCS system. Which type of port should you use to accomplish this task?

    • A. FCoE storage
    • B. server
    • C. FCoE uplink
    • D. uplink

    Answer: C

    Explanation: Server and Uplink Ports on the Fabric Interconnect
    Each fabric interconnect has a set of ports in a fixed port module that you can configure as either server ports or uplink Ethernet ports. These ports are not reserved. They cannot be used by a Cisco UCS instance until you configure them. You can add expansion modules to increase the number of uplink ports on the fabric interconnect or to add uplink Fibre Channel ports to the fabric interconnect.
    You need to create LAN pin groups and SAN pin groups to pin traffic from servers to an uplink port. Each fabric interconnect can include the following types of ports:
    Server Ports
    Server ports handle data traffic between the fabric interconnect and the adapter cards on the servers.
    You can only configure server ports on the fixed port module. Expansion modules do not include server ports.
    Uplink Ethernet Ports
    Uplink Ethernet ports handle Ethernet traffic between the fabric interconnect and the next layer of the network. All network-bound Ethernet traffic is pinned to one of these ports.
    By default, Ethernet ports are unconfigured. However, you can configure them to function in the following ways:
    300-160 dumps exhibit Server
    300-160 dumps exhibit Uplink
    300-160 dumps exhibit FCoE
    300-160 dumps exhibit Appliance
    You can configure uplink Ethernet ports on either the fixed module or an expansion module.
    Uplink Fibre Channel Ports
    Uplink Fibre Channel ports handle FCoE traffic between the fabric interconnect and the next layer of the network. All network-bound FCoE traffic is pinned to one of these ports.
    By default, Fibre Channel ports are uplink. However, you can configure them to function as Fibre Channel storage ports. This is useful in cases where a Cisco UCS requires a connection to a Direct-Attached Storage (DAS) device.
    You can only configure uplink Fibre Channel ports on an expansion module. The fixed module does not include uplink Fibre Channel ports.

    100% Valid and Newest Version 300-160 Questions & Answers shared by 2passeasy, Get Full Dumps HERE: https://www.2passeasy.com/dumps/300-160/ (New 132 Q&As)