NEW QUESTION 1
Which technology can you use to create separate routing tables for different tenants that are hosted on the same Cisco NX-OS platform?
Answer: D
Explanation: http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/nx-os/vxlan/configuration/guide/b_NX-OS_VXL
NEW QUESTION 2
In a three-tier SAN topology, which network layer should you connect the SAN initiators to?
Answer: C
NEW QUESTION 3
When migrating an existing data center network to a unified fabric network, which transitions should you expect to see?
Answer: C
NEW QUESTION 4
Which option accurately describes the OSPF Graceful Restart feature in Cisco NX-OS?
Answer: D
Explanation: A graceful restart, or nonstop forwarding (NSF), allows OSPFv2 to remain in the data forwarding path through a process restart. When OSPFv2 needs to perform a graceful restart, it sends a link-local opaque (type 9) LSA, called a grace LSA
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/4_2/nx-os/unicast/configuration/guide/l3_cli_nxos
NEW QUESTION 5
Why would you configure FCoE to use jumbo frames?
Answer: B
NEW QUESTION 6
Which statement accurately describes the configuration requirements for disjoint Layer 2 networks on Cisco UCS?
Answer: D
NEW QUESTION 7
Spanning Tree Protocol runs at which functional layer of the data center?
Answer: B
NEW QUESTION 8
LISP provides which capability?
Answer: B
NEW QUESTION 9
Which statement accurately describes VSAN-based QoS when the same flow is present in two class maps that are associated to a policy map?
Answer: C
Explanation: http://www.cisco.com/en/US/products/ps5989/products_configuration_guide_chapter09186a0080663141.html
NEW QUESTION 10
You are configuring a switch as a LISP xTR. You plan to use the LISP xTR when deploying redundant map servers. Which action do you take?
Answer: C
NEW QUESTION 11
Which two actions must be performed when you configure Cisco VN-Link in hardware? (Choose two.)
Answer: AC
NEW QUESTION 12
Which technology uses TCP as a block I/O transport?
Answer: A
NEW QUESTION 13
Refer to the Exhibit.
You need to allocate all interfaces on the same port ASIC to the same VDC. Which ports share an ASIC?
Answer: A
NEW QUESTION 14
You are designing a Cisco Fabric interconnect blade chassis and stand alone UCS server solution for a large public cloud provider the design includes these items
One upstream cisco nexus 7000 series switches that provides LAN and SAN connectivity Ten Fabric interconnect switches (five pair in high availability)
Five fully equipped cisco UCS blade chassis per fabric interconnect switches pair Fifty cisco UCS stand alone servers
Which statement ae true regarding San connections from the fabric interconnect switches to the upstream cisco nexus 7000 series switch? (choose two)
Answer: AD
NEW QUESTION 15
Which two options represent an access layer solution designed to accelerate server virtualization, that is managed just like other network devices in the data center? (Choose two)
Answer: CE
Explanation: When server virtualization is implemented, the edge of the network is pushed from the traditional location in the network access layer, implemented in physical switches, to the virtual network access layer that is implemented in software in the server hypervisor. The Cisco Nexus 1000V Switch is an intelligent virtual network access layer switch that runs Cisco NX-OS Software, Cisco's data center operating system that runs on all Cisco data center products. Operating inside the Microsoft Hyper-V hypervisor, the Cisco Nexus 1000V supports Cisco Virtual Network Link (VN-Link) server virtualization technology to provide:
Policy-based virtual machine connectivity
Mobile virtual machine security and network policy
Nondisruptive operating model for your server virtualization and networking teams
When server virtualization is implemented in the data center, servers and virtual machines are not managed the same way as physical servers. Server virtualization is treated as a special deployment, leading to longer
deployment time, with more coordination needed among server, network, storage, and security administrators. With the Cisco Nexus 1000V, you have a consistent networking feature set and configuration and provisioning model for both the physical and the virtual networks. Virtual machine networks can use the same network configuration, security policy, diagnostic tools, and operating models as physical server deployments that are connected to physical switches. This unified approach provides faster deployment and troubleshooting and makes the administration of virtualization environments essentially the same as for nonvirtualized deployments.
Developed in close collaboration with Microsoft, the Cisco Nexus 1000V Switch is certified by Microsoft and integrates with Microsoft Windows Server and Microsoft System Center Virtual Machine Manager
(SCVMM). You can use the Cisco Nexus 1000V to manage your virtual machine connectivity with confidence
in the integrity of the server virtualization infrastructure.
Cisco Nexus 1000V Switch Components
Cisco Nexus 1000V Switches have two main components:
Virtual supervisor module (VSM)
Virtual Ethernet module (VEM)
The VSM provides the switch control and management plane, and the VEM provides the data plane for the switch (Figure 1). The VSM can run as a virtual machine on any Microsoft Hyper-V host or as a virtual service node on the Cisco Nexus 1010 and 1110. The VEM runs as a plug-in (extension) to the Microsoft Hyper-V switch in the hypervisor kernel, providing switching between virtual machines.
Cisco Nexus 1000V sees the VSMs and VEMs as modules. In the current release, a single VSM can manage up to 64 VEMs. The VSMs are always associated with slot numbers 1 and 2 in the virtual chassis. The VEMs are sequentially assigned to slots 3 through 66 based on the order in which their respective hosts were added to the Cisco Nexus 1000V Switch.
NEW QUESTION 16
Which two components are contained within a device package that is installed on a cisco APIC?
Answer: CD
NEW QUESTION 17
Which two FEX topologies trade deterministic bandwidth for server-link stability during FEX uplink failure? (Choose two.)
Answer: AC
NEW QUESTION 18
Drag and drop the feature descriptions from the left onto the correct types of VDCs on the right
Answer:
Explanation:
NEW QUESTION 19
You must use one logical uplink for Fibre Channel traffic and Ethernet traffic on a Cisco UCS system. Which type of port should you use to accomplish this task?
Answer: C
Explanation: Server and Uplink Ports on the Fabric Interconnect
Each fabric interconnect has a set of ports in a fixed port module that you can configure as either server ports or uplink Ethernet ports. These ports are not reserved. They cannot be used by a Cisco UCS instance until you configure them. You can add expansion modules to increase the number of uplink ports on the fabric interconnect or to add uplink Fibre Channel ports to the fabric interconnect.
You need to create LAN pin groups and SAN pin groups to pin traffic from servers to an uplink port. Each fabric interconnect can include the following types of ports:
Server Ports
Server ports handle data traffic between the fabric interconnect and the adapter cards on the servers.
You can only configure server ports on the fixed port module. Expansion modules do not include server ports.
Uplink Ethernet Ports
Uplink Ethernet ports handle Ethernet traffic between the fabric interconnect and the next layer of the network. All network-bound Ethernet traffic is pinned to one of these ports.
By default, Ethernet ports are unconfigured. However, you can configure them to function in the following ways:
Server
Uplink
FCoE
Appliance
You can configure uplink Ethernet ports on either the fixed module or an expansion module.
Uplink Fibre Channel Ports
Uplink Fibre Channel ports handle FCoE traffic between the fabric interconnect and the next layer of the network. All network-bound FCoE traffic is pinned to one of these ports.
By default, Fibre Channel ports are uplink. However, you can configure them to function as Fibre Channel storage ports. This is useful in cases where a Cisco UCS requires a connection to a Direct-Attached Storage (DAS) device.
You can only configure uplink Fibre Channel ports on an expansion module. The fixed module does not include uplink Fibre Channel ports.