C9010-022 Exam - IBM AIX Administration V1

certleader.com

Q1. - (Topic 3) 

What action will prevent the nfsd subsystem from activating at boot time? 

A. Update /etc/inetd.conf to remove the call to startsrc for the NFS subsystem group. 

B. Change the Action attribute from 'wait' to 'once' for the rcnfs line within the /etc/inittab. 

C. Remove the /etc/exports file. 

D. Amend the permissions of/etc/rc.tcpip file to remove execution rights. 

Answer:

Q2. - (Topic 4) 

An administrator attempts to install the fileset tivoli.tsm.client, but it fails due to missing requisites. 

The administrator copies the required filesets into the install directory and tries the preview install again. It fails with the same results, as shown in the graphic below. 

What must the administrator do to successfully install the filesets? 

A. Remove the .toe file or run inutoc. 

B. Provide the correct version of xlsmp.rte. 

C. Make the permissions of all of the filesets group executable 

D. Make the permissions of the requisite filesets group readable 

Answer:

Q3. - (Topic 1) 

AIX hasbeen installed on an LPAR with 32 GB of memory. What should be checked first, before increasing the paging space beyond the default 512MB? 

A. The maximum memory attribute in the LPAR profile. 

B. Quantity and size of hosted filesystems. 

C. Disk device distribution and utilization. 

D. Paging requirements of applications that will be hosted. 

Answer:

Q4. - (Topic 3) 

An AIX LPAR has virtual disks presented by a VIO Server and the administrator would like to determine the size of hdisk0. Which command will show this information? 

A. Isdev 

B. Iquervpv 

C. Isattr 

D. getconf 

E. Iscfq 

Answer:

Topic 4, Volume D 

Q5. - (Topic 2) 

How can administrators ensure that the Integrated Virtual Ethernet (IVE) adapters in their servers have the latest available firmware? 

A. By upgrading the given IBM Power Systems server to the latest available system firmware. 

B. By using inventory scout to query the installed firmware level against the available level. 

C. By using either the managing HMC, SDMC or IVM to query and update the adapter firmware. 

D. By using the Ismcode AIX command with the query flag. 

Answer:

96. - (Topic 2) 

What is required to support VLANs in an AIX partition? 

A. IEEE 802.1Q compatible adapter 

B. Promiscuous mode disabled 

C. IEEE 802.3ad compatible interface 

D. QoS must be enabled 

Q6. - (Topic 3) 

An administrator would like to update a VIO Server (VIOS) to the latest maintenance level. 

Which command, run from the restricted shell, will update the operating system on VIOS? 

A. vios_update 

B. update_all 

C. install-all 

D. updateios 

Answer:

Q7. - (Topic 3) 

Which command will show the status of Geographically Mirrored Volume Groups? 

A. gmvgstat 

B. geovgstat 

C. Isglvm 

D. listgm 

Answer:

135. - (Topic 3) 

Which startup script will mount all filesystems in /etc/filesystems for which the mount parameter is set to 'true'? 

A. /etc/rc 

B. /etc/red 

C. /sbin/rc.start 

D. /etc/rc.bootc 

Q8. - (Topic 4) 

Which command can be used to monitor I/O activity? 

A. cpio 

B. alstat 

C. iostat 

D. vmstat 

Answer:

Q9. - (Topic 4) 

An administrator receives the following error message when attempting to extend a volume group with an additional disk: 

0516-1162 extendvg : the Physical Partition size of 256 requires thecreation of 1026 partitions for hdisk2. The limitation for volume group rootvg is 1024 physical partitions per physical volume. Use the chvg command with the -t option to attempt to change the maximum PhysicalPartitions per Physical volume for this volume group. 

While the use of the -t option may allow the administrator to successfully extend the volume group, what other effect will using this option have? 

A. The boot logical volume would be recreated. 

B. The volume group would need to be varied off to apply the change. 

C. Mirroring would be removed from all logical volumes within the volume group 

D. The number of physical volumes allowed in the volume group will be reduced 

Answer:

197. - (Topic 4) 

An administrator needs to update both VIO Servers in a dual VIO Server environment 

Prior to updating the first VIO Server, what action should be taken on the vSCSI client partitions to ensure they have access to the disk hosted from the secondVIO Server? 

A. Verily that the path to the disk is active using ispath. 

B. The map of the VIO Server environment must be verified with ismap. 

C. The secondary path must be manually redesignated as the primary using chpath. 

D. A snapshot of the disk on thefirst VIO Server must be compared with the second using viosbr. 

Q10. - (Topic 1) 

Which AIX command will display the virtual SCSI slot number that is the parent of hdisk0? 

A. Isdev 

B. Iscfg 

C. Isattr 

D. Ismap 

Answer: